How many Smart-Ex Intrinsically Safe barcode scanner wireless can be connected to one PC in 1 time.
14/Dec/2017
Here´s the result:
Firmware Version 1.1.0.1 (Ident-Ex as Slave) Maximum active HID connections: 9 Maximum active SPP connections: 7 Firmware Version 1.6.10.0 (Ident-Ex as Master) Maximum active HID connections: 5 Maximum active SPP connections: 2 If the maximum numbers of active connections was reached and a new connection will be established, two thinks could happen:- The connection could not be established
- The connection will be established and another active connection will be lost
Reading and writing data to all connected devices is possible, also if 9 devices were connected with HID Profile. If “HID Autoconnect” was enabled and more Ident-Ex’s than the maximum number of active connections were in range, the devices who can establish a connection accords to the random principle. The maximum numbers of active connections is limited by the Bluetooth module of the PC (normally up to 7 active connections). Tested with Broadcom 2070 Bluetooth Module.
|